How to operate and maintain the air floatation machine
1 skill parameter
(1) as usual, the reaction time is 15 minutes.
(2) the rising velocity of the air bearing area in the war room is 47mm/ seconds, and the dispersion is 0.46mm/ seconds.
(3) as usual reflux ratio of 30%, the disposal of the punishment of 0.25 - 0.4m3/ hours.
2 operation control
(1) with a good coagulant dosing device, and to start the air compressor, the compressed input of dissolved gas atmosphere.
(2) ratio and pressure solution tank pressure reach 2 - being, start with electric single-phase electric water pump, then slow to open the valve, net water input saturator held dissolved gas, but to detailed level meter.
(3) and the dissolving tank liquid level gauge water level reaches 1/3, open the valve will release the dissolved gas and water input reaction pool.
(4) regulating valve of water pump, the water level link in 1 / 3, 1 / 2; spineless floating pool drain valve, water level makes the link at the discharging port, and then began to normal operation.
3 meticulous work
(1) in the use of the former, to deal with the deployment of electrical equipment to complete the deployment of a thorough examination, check whether the normal.
(2) to keep detailed pressure saturator pressure cannot exceed 4kgcm2.
(3) single-phase electric pump cannot break, more cannot no-load operation, so as not to damage the single-phase electric water pump.
(4) to link release is clean, if the release is blocked, it will affect the flotation results.
(5) can not use wet hand to fight with point switch, socket, etc., if necessary inspection, should be held by the electrician.
4 maintenance maintenance
(1) the operation of equipment deployment should be operated according to the relevant process control rules, and the operation of the equipment is strictly prohibited.
(2) to admire set equipment deployed instruments, where corrosive chemical materials, should stop and electrical appliances, metal contact, so as not to be corrupted.
(3) after the end of operation, should washing set up equipment to deploy instruments for use again.